Industrial Power Fuses

37x54mm Low-Voltage Fuse

Breaking Capacity

This series of products are round tube bolt-connected fuses for partial protection. They have the characteristics of strong current limiting capacity, high breaking capacity, fast short-circuit breaking speed, etc., and can withstand temperature shock, mechanical vibration/impact, current shock, chemical Load, suitable for road vehicle industry applications, can be used as short circuit and backup protection for electric vehicle drive power systems, power conversion systems, energy storage and power batteries, energy storage capacitors, frequency conversion controllers, chargers, wires and other automotive components and equipment .


The interrupting capacity should reach the interrupting rated current given in the following table. And after this test, there should be no damage of the fuse-tube or shattering of the caps. After this test, the insulation resistance between the end caps shall be not less than 0.1MΩ.


Rated Voltage Rated Current Breaking Capacity
DC750V/AC690V 180A-400A AC100KA/DC 50KA


Techinical Data

Model Product Code Rated current(A) I2t (A2Sec) Power(W) Installation torque
Forearc Fuse
38C 38C-3180-I/G 180 1358 13230 39.0 Mounting bolt M10 recommended torque 20Nm
38C-3200-I/G 200 2548 17760 40.0
38C-3250-I/G 225 3552 25200 42.8
38C-3250-I/G 250 4990 35600 47.5
38C-3280-I/G 280 6860 51000 48.2
38C-3315-I/G 315 9760 71600 54.5
38C-3350-I/G 350 14100 96600 55.6
38C-3400-I/G

400

18500

125000

58.0

Size Chart


● Pending


○ Approvals